Drager Interlock 7500 Alcohol block

€1,250.00 EUR


▪️ Turite klausimų dėl šios prekės❓Galime pakonsultuoti telefonu +370 683 90000, arba mūsų salone Armatūrininkų g. 1, Kaunas.
📩 Taip pat galite siųsti mums užklausą į kurią atsakysime per 24 val.

Home delivery from €4.99

Venipak courier within 1-2 working days.

Collect in store €0

Armaturininkai str. 1, Kaunas
Working hours: IV 9:00-18:00

The Dräger Interlock 7500 is a vehicle immobilizer breathalyzer that replaces the reliable, previous Dräger Interlock® 7000 model.

Suitable for drivers who are subject to an administrative penalty - a ban on driving vehicles that are not equipped with anti-alcohol engine locks. The device is delivered configured according to the requirements of the LRV description, along with a mandatory certificate.

Attention - installation of the device depends on the type, model and installation location of the vehicle, therefore installation is not included in the price. Only approved service centers have the right to install the device and provide the relevant certificate, we can offer this service in many cities of Lithuania. For installation of the device in your vehicle, please contact us separately.

Our service contacts: +370 614 30000

Interlock 7500 prevents an intoxicated person from starting the vehicle's engine or turning on another device.

Before starting the trip, the driver's sobriety is checked (the driver blows into the breathalyzer).
If the concentration of alcohol in the breath of the driver is detected above the set limit, the device blocks the engine starting system.

Meets European and Lithuanian blocking breathalyzer standards (LST EN 50436-1:2014, LST EN 50436-2:2014, LST EN 50436-6:2015).

PROPERTIES

-Wide operating temperature range from -40º C to +85ºC.
-Interlock® 7500 is ready for work very quickly, even at extremely low temperatures.
- At a temperature of 0º C - the alcoblock is ready for work in less than 5 seconds.
- Can be equipped with a video camera.
- Possible interface with GPS monitoring, car fleet management systems.
-200,000 record memory.
-Dräger Interlock 7500 uses less than 1 mA of power in standby mode.
- Mouth alcohol detection function.
-Dräger Interlock 7500 meets the strictest data protection requirements.
- Data is coded and protected, complies with LST EN 50436-6:2015.
-The blowing nozzle is located on the back wall of the breathalyzer.

-Category Alcoblock
- Country of manufacture Germany
-Sensor Dräger electrochemical (heated)
-Blow flow control The strength and time of blowing is controlled, the system adapts to the lungs
- Mouth alcohol residue detection Has the ability to detect alcohol left in the mouth. If the device detects that the result is affected by alcohol remaining in the oral cavity or upper respiratory tract, a corresponding measurement error message is displayed.
-Temperature sensor If the temperature is not right, the test is not allowed. Temperature compensation is used, which ensures a particularly accurate result.
-Measurement units As required
-Calibration is possible
-Calibration frequency Once a year
-Compliance with standards Complies with LST EN 50436-1:2014, LST EN 50436-2:2014
- Screen Graphic with backlight
-The language of screen messages can be changed to Lithuanian or others through the user menu
-Preparation time <5 sec. at 0°C; <60 sec. at -20°C; <110 sec. at -40°C
- Power supply 12V / 24V
-Memory for 200,000 events
-GPS Available GPS / GPRS accessory
-Working temperature -40 - 85°C
-Size Handpiece 138mm x 61mm x 36mm, Control Unit 148mm x 90mm x 32mm
-Weight 178g
-Composition of the set Breathalyzer (handpiece), control unit 12/24V, spring cable 1.5 meters (stretches to 2.5 - 3.0 meters), 3 blowing nozzles, holder for fixing the handpiece, wires required for normal connection, 6 cambrics , instruction manual in Lithuanian.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

The Dräger Interlock 7500 is a vehicle immobilizer breathalyzer that replaces the reliable, previous Dräger Interlock® 7000 model.

Suitable for drivers who are subject to an administrative penalty - a ban on driving vehicles that are not equipped with anti-alcohol engine locks. The device is delivered configured according to the requirements of the LRV description, along with a mandatory certificate.

Attention - installation of the device depends on the type, model and installation location of the vehicle, therefore installation is not included in the price. Only approved service centers have the right to install the device and provide the relevant certificate, we can offer this service in many cities of Lithuania. For installation of the device in your vehicle, please contact us separately.

Our service contacts: +370 614 30000

Interlock 7500 prevents an intoxicated person from starting the vehicle's engine or turning on another device.

Before starting the trip, the driver's sobriety is checked (the driver blows into the breathalyzer).
If the concentration of alcohol in the breath of the driver is detected above the set limit, the device blocks the engine starting system.

Meets European and Lithuanian blocking breathalyzer standards (LST EN 50436-1:2014, LST EN 50436-2:2014, LST EN 50436-6:2015).

PROPERTIES

-Wide operating temperature range from -40º C to +85ºC.
-Interlock® 7500 is ready for work very quickly, even at extremely low temperatures.
- At a temperature of 0º C - the alcoblock is ready for work in less than 5 seconds.
- Can be equipped with a video camera.
- Possible interface with GPS monitoring, car fleet management systems.
-200,000 record memory.
-Dräger Interlock 7500 uses less than 1 mA of power in standby mode.
- Mouth alcohol detection function.
-Dräger Interlock 7500 meets the strictest data protection requirements.
- Data is coded and protected, complies with LST EN 50436-6:2015.
-The blowing nozzle is located on the back wall of the breathalyzer.

-Category Alcoblock
- Country of manufacture Germany
-Sensor Dräger electrochemical (heated)
-Blow flow control The strength and time of blowing is controlled, the system adapts to the lungs
- Mouth alcohol residue detection Has the ability to detect alcohol left in the mouth. If the device detects that the result is affected by alcohol remaining in the oral cavity or upper respiratory tract, a corresponding measurement error message is displayed.
-Temperature sensor If the temperature is not right, the test is not allowed. Temperature compensation is used, which ensures a particularly accurate result.
-Measurement units As required
-Calibration is possible
-Calibration frequency Once a year
-Compliance with standards Complies with LST EN 50436-1:2014, LST EN 50436-2:2014
- Screen Graphic with backlight
-The language of screen messages can be changed to Lithuanian or others through the user menu
-Preparation time <5 sec. at 0°C; <60 sec. at -20°C; <110 sec. at -40°C
- Power supply 12V / 24V
-Memory for 200,000 events
-GPS Available GPS / GPRS accessory
-Working temperature -40 - 85°C
-Size Handpiece 138mm x 61mm x 36mm, Control Unit 148mm x 90mm x 32mm
-Weight 178g
-Composition of the set Breathalyzer (handpiece), control unit 12/24V, spring cable 1.5 meters (stretches to 2.5 - 3.0 meters), 3 blowing nozzles, holder for fixing the handpiece, wires required for normal connection, 6 cambrics , instruction manual in Lithuanian.