All in one control unit HDL-MHRCU.433 Hotel RCU

€576.45 EUR

Home delivery from €4.99

Venipak courier within 1-2 working days.

Collect in store €0

Armaturininkai str. 1, Kaunas
Working hours: IV 9:00-18:00

This module is capable of combining full-fledged control of lighting and other devices in a small house, apartment or hotel room.

  • 13 units relay outputs 5A
  • 4 pcs. relay outputs 10A
  • 24 pcs. dry contacts
  • There will be a connection
  • 4 pcs. Dimer 1A
  • Lan connection

A new generation of hotel Guest Room Control Unit which supports Hotel Host control, Mix control, Dry contact input, doorbell functions, and LED indication functions.

  • Working voltage: DC20-30V
  • Static power consumption: 60mA / DC24V
  • Dynamic power consumption: 300mA / DC24V
  • Signal interface: HDL Buspro, RJ45, INNER Buspro
  • RJ45 interface: UDP/IP network interface
  • TRIAC: 16A TRIAC, minimum load is 30w
  • Buspro terminal: single-core cables 0.75-0.85 mm
  • Relay output: 5A / 10A
  • Dimensions: 216 x 90 x 56 mm / Weight: 725g
  • Degree of protection: IP20

All in one

This multifunctional unit is capable of mixed relay output, dry contact input, dual communication protocols, and doorbell functions. It can also control and monitor different targets and devices such as panels, curtains, doorbells, lamps, fans, and air conditioning, etc.

Dual interfaces

Both RJ45 and HDL Buspro interfaces are supported. The RJ45 IP interface enables the unit to connect to the existing Ethernet network in a hotel; this allows the hotel property management system and the hotel management software to share check-in/check-out data, and other valuable information. The HDL Buspro interface is used to connect modules in the HDL Buspro network like panels, doorbells, and sensors, etc.

Relay output

The 17 channels which the RCU can output either 5A or 10A, these outputs enable the control of Incandescent lamps, halogen lamps, and low voltage halogen lamps.

Doorbell functionality

Doorbell LED indication is supported and controlled via 5 dedicated channels from the RCU, this enables the doorbell to display the room number, and laundry, cleaning, and DND status.

Dry contact input

A total of 24 dry contact inputs can be used as control targets via the hotel management software. It also enables the dry contact inputs to work with the LED outputs to manage and control 3rd party doorbells.

Viskas viename  kontroliavimo blokas HDL-MHRCU.433 Hotel RCU Išmanūs namai HDL AUTOGARSAS.LT
HDL

All in one control unit HDL-MHRCU.433 Hotel RCU

€576.45 EUR

This module is capable of combining full-fledged control of lighting and other devices in a small house, apartment or hotel room.

A new generation of hotel Guest Room Control Unit which supports Hotel Host control, Mix control, Dry contact input, doorbell functions, and LED indication functions.

DESCRIPTION

All in one

This multifunctional unit is capable of mixed relay output, dry contact input, dual communication protocols, and doorbell functions. It can also control and monitor different targets and devices such as panels, curtains, doorbells, lamps, fans, and air conditioning, etc.

Dual interfaces

Both RJ45 and HDL Buspro interfaces are supported. The RJ45 IP interface enables the unit to connect to the existing Ethernet network in a hotel; this allows the hotel property management system and the hotel management software to share check-in/check-out data, and other valuable information. The HDL Buspro interface is used to connect modules in the HDL Buspro network like panels, doorbells, and sensors, etc.

Relay output

The 17 channels which the RCU can output either 5A or 10A, these outputs enable the control of Incandescent lamps, halogen lamps, and low voltage halogen lamps.

Doorbell functionality

Doorbell LED indication is supported and controlled via 5 dedicated channels from the RCU, this enables the doorbell to display the room number, and laundry, cleaning, and DND status.

Dry contact input

A total of 24 dry contact inputs can be used as control targets via the hotel management software. It also enables the dry contact inputs to work with the LED outputs to manage and control 3rd party doorbells.

DOCUMENTS

More information

User manual (EN)

View product

This module is capable of combining full-fledged control of lighting and other devices in a small house, apartment or hotel room.

  • 13 units relay outputs 5A
  • 4 pcs. relay outputs 10A
  • 24 pcs. dry contacts
  • There will be a connection
  • 4 pcs. Dimer 1A
  • Lan connection

A new generation of hotel Guest Room Control Unit which supports Hotel Host control, Mix control, Dry contact input, doorbell functions, and LED indication functions.

  • Working voltage: DC20-30V
  • Static power consumption: 60mA / DC24V
  • Dynamic power consumption: 300mA / DC24V
  • Signal interface: HDL Buspro, RJ45, INNER Buspro
  • RJ45 interface: UDP/IP network interface
  • TRIAC: 16A TRIAC, minimum load is 30w
  • Buspro terminal: single-core cables 0.75-0.85 mm
  • Relay output: 5A / 10A
  • Dimensions: 216 x 90 x 56 mm / Weight: 725g
  • Degree of protection: IP20

All in one

This multifunctional unit is capable of mixed relay output, dry contact input, dual communication protocols, and doorbell functions. It can also control and monitor different targets and devices such as panels, curtains, doorbells, lamps, fans, and air conditioning, etc.

Dual interfaces

Both RJ45 and HDL Buspro interfaces are supported. The RJ45 IP interface enables the unit to connect to the existing Ethernet network in a hotel; this allows the hotel property management system and the hotel management software to share check-in/check-out data, and other valuable information. The HDL Buspro interface is used to connect modules in the HDL Buspro network like panels, doorbells, and sensors, etc.

Relay output

The 17 channels which the RCU can output either 5A or 10A, these outputs enable the control of Incandescent lamps, halogen lamps, and low voltage halogen lamps.

Doorbell functionality

Doorbell LED indication is supported and controlled via 5 dedicated channels from the RCU, this enables the doorbell to display the room number, and laundry, cleaning, and DND status.

Dry contact input

A total of 24 dry contact inputs can be used as control targets via the hotel management software. It also enables the dry contact inputs to work with the LED outputs to manage and control 3rd party doorbells.